Geothermal heat pump ProfiK-GEO Series Cube

  • For heating and air conditioning of houses, cottages and hotels.
  • The shape of the housing is designed in such a way that when combining heat pumps in a cascade, it is possible to place the block one above the other.

  • Touch control panel.
  • Individual weather-dependent control (optional remote sensor).
  • Backup source management
  • heating.
  • Ability to control from another source on / off and switching the operating mode.
  • Automatic switching of the mode heating/conditioning.
  • Online monitoring (optional) allows you to see the operation parameters from anywhere in the world (via the Internet).
  • Safe operation of the system due to built-in thermal and current protection, voltage and phase control.

1 Heating capacity, Nom., kW 6.4
2 Cooling capacity, Nom., kW 5.1
3 Power supply, ~/Hz/V 1~/50/230
4 Power consumption Nom. kW 1.5
5 Rated efficiency EER/COP 3.3/4.2
6 Unit sound pressure level, dBA 51
7 Compressor sealed rotary
8 Overall dimensions (HxWxD), mm 650x600x800
9 Recommended fuses, A 20
10 Connection of heating pipes, inch 1_1/4
11 Geocontour pipe connection, inch 1_1/4
1 Heating capacity, Nom., kW 7.6
2 Cooling capacity, Nom., kW 6
3 Power supply, ~/Hz/V 1~/50/230
4 Power consumption Nom. kW 1.9
5 Rated efficiency EER/COP 3.2/4
6 Unit sound pressure level, dBA 51
7 Compressor sealed rotary
8 Overall dimensions (HxWxD), mm 650x600x800
9 Recommended fuses, A 20
10 Connection of heating pipes, inch 1_1/4
11 Geocontour pipe connection, inch 1_1/4
1 Heating capacity, Nom., kW 8.7
2 Cooling capacity, Nom., kW 6.9
3 Power supply, ~/Hz/V 1~/50/230
4 Power consumption Nom. kW 2.2
5 Rated efficiency EER/COP 3.2/4.1
6 Unit sound pressure level, dBA 51
7 Compressor sealed rotary
8 Overall dimensions (HxWxD), mm 650x600x800
9 Recommended fuses, A 20
10 Connection of heating pipes, inch 1_1/4
11 Geocontour pipe connection, inch 1_1/4
1 Heating capacity, Nom., kW 12.7
2 Cooling capacity, Nom., kW 9.9
3 Power supply, ~/Hz/V 3~/50/380
4 Power consumption Nom. kW 2.7
5 Rated efficiency EER/COP 3.7/4.7
6 Unit sound pressure level, dBA 64
7 Compressor spiral
8 Overall dimensions (HxWxD), mm 650x600x800
9 Recommended fuses, A 10
10 Connection of heating pipes, inch 1_1/4
11 Geocontour pipe connection, inch 1_1/4
1 Heating capacity, Nom., kW 16.6
2 Cooling capacity, Nom., kW 13.1
3 Power supply, ~/Hz/V 3~/50/380
4 Power consumption Nom. kW 3.4
5 Rated efficiency EER/COP 3.9/4.9
6 Unit sound pressure level, dBA 64
7 Compressor spiral
8 Overall dimensions (HxWxD), mm 650x600x800
9 Recommended fuses, A 10
10 Connection of heating pipes, inch 1_1/4
11 Geocontour pipe connection, inch 1_1/4
1 Heating capacity, Nom., kW 20.7
2 Cooling capacity, Nom., kW 16.2
3 Power supply, ~/Hz/V 3~/50/380
4 Power consumption Nom. kW 4.1
5 Rated efficiency EER/COP 4.0/5.0
6 Unit sound pressure level, dBA 64
7 Compressor spiral
8 Overall dimensions (HxWxD), mm 650x600x800
9 Recommended fuses, A 16
10 Connection of heating pipes, inch 1_1/4
11 Geocontour pipe connection, inch 1_1/4
1 Heating capacity, Nom., kW 22.4
2 Cooling capacity, Nom., kW 17.5
3 Power supply, ~/Hz/V 3~/50/380
4 Power consumption Nom. kW 4.9
5 Rated efficiency EER/COP 3.6/4.6
6 Unit sound pressure level, dBA 64
7 Compressor spiral
8 Overall dimensions (HxWxD), mm 650x600x800
9 Recommended fuses, A 20
10 Connection of heating pipes, inch 1_1/4
11 Geocontour pipe connection, inch 1_1/4